An architect is sizing the workloads that will run in a new VMware Cloud Foundation (VCF) Management Domain. The customer has a requirement to use Aria Operations to provide effective monitoring of the new VCF solution. What is the minimum Aria Operations Analytics node size requirement when AriaSuite Lifecycle is in VCF-aware mode?
A customer is deploying VCF at a new datacenter location. They will migrate their workloads from the existing datacenter to the new VCF platform over six months. Both datacenters will run simultaneously for six months during the migration. Which of the following should be a documented risk?
An architect decided to deploy an NSX Edge cluster using SDDC Manager. These Edges will be used by a Tier-0 Gateway configured with BGP to provide North-South connectivity in the Management Domain. Which statement justifies this design decision?
During a design discussion, the VMware Cloud Foundation Architect was presented with a requirement to reduce power utilization across all workload domains including management. The architect has suggested to use vSphere Distributed Power Management (DPM) to satisfy this requirement. Which recommendation should the architect provide?
An architect is planning resources for a new cluster that will be integrated into an existing VI Workload Domain. The cluster’s primary purpose is to support a mission-critical application with five resource-intensive virtual machines. Which design recommendation should the architect provide to prevent resource bottlenecks while meeting the N+1 availability requirement and keeping the overall investment cost minimal?
An architect is designing a new VMware Cloud Foundation (VCF) solution. During the discovery workshops, the customer explained that the solution will initially be used to host a single business application and some internal management tooling. The customer provided the following background information:
The business application consists of two virtual machines.
The business application is sensitive to changes in its storage I/O.
The business application must be available during the company’s business hours of 9 AM - 5 PM on weekdays.
The architect has made the following design decisions in response to the customer’s requirements and the additional information provided during discovery:
The solution will use the VCF consolidated architecture model.
A single cluster will be created, consisting of six ESXi hosts.
Which design decision should the architect include in the design to mitigate the risk of impacting the business application?
An architect is designing a new VMware Cloud Foundation (VCF)-based Private Cloud solution. During the requirements gathering workshop, a stakeholder from the network team stated that:
The solution must ensure that any physical networking component is redundant to N+N.
The solution must ensure inter-datacenter network links are diversely routed.
When writing the design documentation, how should the architect classify the stated requirement?
An architect is working with an organization on the creation of a new Private Cloud Platform. The organization has provided the following business objectives they wish to achieve with the new platform:
• Reduce the operating costs associated with running separate areas of hosting capacity and separate/duplicate systems.
• Reduce the risks, time, and effort associated with managing platforms that are out of vendor support.
• Reduce the operating costs associated with Public Cloud usage.
• Reduce the risks associated with having incomplete documentation for application inventory and dependency mappings.
They have grouped these business objectives into a set of use cases:
• Migration - Provide a platform that supports the migration of virtualized workloads from existing platforms.
• Containerization - Provide a platform that supports the deployment of containerized workloads.
• Centralization and Consolidation - Provide a central private cloud platform accessible to all relevant areas of the business.
When considering these objectives and use cases, what should the architect include in the design documentation as a part of the Conceptual Model?
An architect is tasked with designing a new VMware Cloud Foundation environment and has identified the following customer-provided requirements:
REQ01: The application server must handle at least 30,000 transactions per second.
REQ02: The design must meet ISO 27001 information security standards.
REQ03: The storage network should maintain a minimum latency of 12 milliseconds before path failover.
REQ04: The staging environment should utilize a secondary third-party data center.
REQ05: Planned maintenance must be performed outside the hours of 8 AM to 8 PM GMT.
What are the two functional requirements? (Choose two.)
The following requirements were identified in an architecture workshop for a virtual infrastructure design project.
REQ001: All virtual machines must satisfy the Recovery Point Objective (RPO) of fifteen (15) minutes or less in a disaster recovery (DR) situation
REQ002: Service level availability must satisfy 99.999% measured yearly.
Which two test cases will validate these requirements?
Due to limited budget and hardware, an administrator is constrained to a VMware Cloud Foundation (VCF) consolidated architecture of seven ESXi hosts in a single cluster. An application that consists of two virtual machines hosted on this infrastructure requires minimal disruption to storage I/O during business hours. Which two options would be most effective in mitigating this risk without reducing availability? (Choose two.)
A customer defined a requirement for the newly deployed SDDC infrastructure which will host one of the applications responsible for video streaming. Application will run as part of a VI Workload Domain with dedicated NSX instance and virtual machines. Required network throughput was defined as 250 Gb/s. Additionally, the application should provide the lowest possible latency. Which design decision should be recommended by an architect for the NSX Edge deployment?
An architect is planning the deployment of Aria components in a VMware Cloud Foundation environment using SDDC Manager and must prepare a logical diagram with networking connections for particular Aria products. Which are two valid Application Virtual Networks for Aria Operations deployment using SDDC Manager? (Choose two.)
During the requirements gathering workshop for a new VMware Cloud Foundation (VCF)-based Private Cloud solution, the customer states that the solution must:
• Provide a single interface for monitoring all components of the solution.
• Minimize the effort required to maintain the solution to N-1 software versions.
When creating the design document, under which design quality should the architect classify these stated requirements?
An architect is designing a VMware Cloud Foundation (VCF)-based private cloud solution for a customer. During the requirements gathering workshop, the customer provided the following requirement:
All SSL certificates should be provided by the company’s certificate authority.
When creating the design, how should the architect classify this stated requirement?
An architect is preparing a VI Workload Domain design with a dedicated NSX instance. The workload domain is planned to grow up to 300 ESXi hosts within the next six months. Which is the minimum NSX Manager form factor that should be recommended by the architect for this VI Workload Domain to support the forecasted growth?
An architect is working with a service provider to design a VMware Cloud Foundation (VCF) solution that is required to host workloads for multiple tenants. The following requirements were gathered:
Each tenant requires full access to their own vCenter.
Each tenant will utilize and manage their own identity provider for access.
A total of 28 tenants are expected to be onboarded.
Each tenant will have their own independent VCF lifecycle maintenance schedule.
Which VCF architecture option will meet these requirements?
A company plans to expand its existing VMware Cloud Foundation (VCF) environment for a new application. The current VCF environment includes a Management Domain and two separate VI Workload Domains with different hardware profiles. The new application has the following requirements:
The application will use significantly more memory than current workloads.
The application will have a limited number of licenses to run on hosts.
Additional VCF and hardware costs have been approved for the application.
The application will contain confidential customer information that requires isolation from other workloads.
What design recommendation should the architect document?
During a requirements gathering workshop, several Business and Technical requirements were captured from the customer. Which requirement will be classified as a Business Requirement?
A VMware Cloud Foundation design incorporates the following technical requirements:
All management components must have their login sessions timeout after 2 minutes of inactivity.
Communication between management components should be limited to required ports only.
Modifications required by compliancy should not impact the management components’ functionality.
What would be the recommendation from a design perspective that would aid in achieving the above requirements?
An architect is designing a new VCF solution to meet the following requirements:
The solution must be deployed across two availability zones.
The physical hosts must be installed in a single rack per availability zone.
Workloads running in the cluster must be able to run on hosts in either availability zone.
The architect has decided that to meet these requirements, the solution will be deployed using the Single Instance - Multiple Availability Zones VCF Topology. When considering the design for the network, what should the architect include in the logical design to meet these requirements?
An architect is designing a VMware Cloud Foundation (VCF)-based Private Cloud solution. During the requirements gathering workshop with the customer stakeholders, the following information was noted:
In the event of a site-level disaster, the solution must enable all production workloads to be restarted in the secondary site.
In the event of a host failure, workloads must be restarted in priority order.
When creating the design documentation, which design quality should be used to classify the stated requirements?
During the requirements capture workshop, the customer expressed a plan to use Aria Operations Continuous Availability to satisfy the availability requirements for a monitoring solution. They will validate the feature by deploying a Proof of Concept (POC) into an existing low-capacity lab environment. What is the minimum Aria Operations analytics node size the architect can propose for the POC design?
A customer has stated the following requirements for Aria Automation within their VCF implementation:
• Users must have access to specific resources based on their company organization
• Developers must only be able to provision to the Development environment
• Production workloads can be placed on DMZ or Production clusters
What two design decisions must be implemented to satisfy these requirements? (Choose two.)
An architect is designing a VMware Cloud Foundation (VCF)-based private cloud solution for a customer that will include two physical locations. The customer has stated the following requirement:
All management tooling must be resilient at the component level within a single site.
When considering the design decisions for VMware Aria Suite components, what should the Architect document to meet the stated requirement?
An architect is designing a new VMware Cloud Foundation (VCF)-based Private Cloud solution. During the requirements gathering workshop, a network team stakeholder stated that:
• The solution must ensure that any physical networking component has N + N redundancy.
• The solution must ensure that inter-datacenter network links are diversely routed.
When documenting the design, how should the architect classify these requirements?
An organization is planning to expand their existing VMware Cloud Foundation (VCF) environment to meet an increased demand for new user-facing applications. The physical host hardware proposed for the expansion is a different model compared to the existing hosts, although it has been confirmed that both sets of hardware are compatible. The expansion needs to provide capacity for management tooling workloads dedicated to the applications, and it has been decided to deploy a new cluster within the management domain to host the workloads. What should the architect include within the logical design for this design decision?