Winter Special - Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: top65certs

Free and Premium Netapp NS0-521 Dumps Questions Answers

Page: 1 / 5
Total 65 questions

Implementation Engineer - SAN ONTAP Exam Questions and Answers

Question 1

A customer asks for help cloning one database LUN from a SnapMlrror destination volume for testing the data with a new application.

What command should the administrator use to clone the LUN?

Options:

A.

volume fileclonecreate

B.

lun wovestart

C.

volumeclone create

D.

volumemove start

Buy Now
Question 2

An administrator finishes an installation of a new NetApp ASA system at the customer site and creates a new LUN. The customer wants to restrict the access of the LUN to specific UFs.

Where would the administrator configure this?

Options:

A.

Zoning

B.

igroup

C.

Selective LUN Map

D.

Portset

Question 3

An SVM is created for FCP traffic. LUNs must be created to share with ESXi hosts for datastores. Which two items must be configured after the LUN is created, for this to happen? (Choose two.)

Options:

A.

Create an igroup with the ESXi hosts' WWPNs.

B.

Create an igroup with the ESXi hosts' WWNNs.

C.

Configure CHAP authentication.

D.

Map the LUNs to the igroup.

Question 4

During an iSCSI deployment, the customer requests a change of front-end network connections on the NetApp ONTAP cluster from twinax cables to fiber-optic cables.

Which two NetApp tools would an administrator use to verify the supported port speeds and transceivers? (Choose two.)

Options:

A.

Hardware Universe to determine supported transceivers

B.

Interoperability Matrix Tool to determine supported transceivers

C.

Hardware Universe to determine supported port speeds

D.

Interoperability Matrix Tool to determine supported port speeds

Question 5

An engineer Is implementing a data migration scenario for a customer who has multiple FC LUNs across multiple third-party SAN arrays. The engineer wants to use Foreign LUN Import (FLI) for the migration.

What is a requirement on the destination NetApp ONTAP cluster for FLI?

Options:

A.

A valid SnapMirror license

B.

At least one FC port in initiator mode

C.

A valid NetApp XCP license

D.

At least one FC port in target mode

Question 6

A customer has data in a LUN on an existing third-party SAN storage system that will be migrated to a new NetApp AFF A400 all-flash MetroCluster system. The host connected to the LUN is a Windows Server 2019 system.

In this scenario, which two methods are supported? (Choose two.)

Options:

A.

SnapMirror Business Continuity

B.

Foreign LUN Import in online mode

C.

Foreign LUN Import in offline mode

D.

Client-side copy of the data

Question 7

A customer requires multiple SAN and NAS protocols on a NetApp AFF cluster. The cluster must concurrently serve a namespace over NVMe/FC, a LUN over FCP, a LUN over iSCSI, and an NFS export.

Based on these requirements, what is the minimum data SVM count that is required?

Options:

A.

3

B.

4

C.

1

D.

2

Question 8

A customer has a two-node NetApp AFF ASA cluster in an environment with a Cisco Fibre Channel SAN and Cisco UCS Servers. The customer wants to upgrade the UCS Server BIOS and the Cisco NX-OS system running on the switches.

Which NetApp resource should be consulted to check compatibility with the new versions?

Options:

A.

Interoperability Matrix Tool (IMT)

B.

BlueXP digital advisor

C.

Hardware Universe

D.

Active IQ Config Advisor

Question 9

What Is modified when moving a LUN between different HA pairs in the same SVM to prevent loss of connectivity?

Options:

A.

port name

B.

reporting nodes

Cigroup

C.

LUN mapping

Question 10

After deleting a LUN, an administrator notices that the space does not show as available. What needs to be done to reclaim the space?

Options:

A.

UnmaptheLUN.

B.

Delete the volume snapshots.

C.

Purge the recovery queue.

D.

Perform space reclamation.

Question 11

What needs to be done to create a consistent Snapshot copy of a LUN without disruptions?

Options:

A.

Ensure that the LUN is the only one in the volume.

B.

Quiesce I/O to the LUN.

C.

Ensure that the LUN Is unmapped from the host.

D.

Map the LUN to a host.

Question 12

An administrator upgraded their NetApp ONTAP software from release 9.10.1 to 9.13.1 on a NetApp All SAN Array (ASA) cluster and is creating a new iSCSI SVM.

Which automatic feature can be used with iSCSI?

Options:

A.

LIF failover

B.

LUN mapping

C.

CHAP authentication

D.

igroup creation

Question 13

What configuration must be applied for NVMe/FC?

Options:

A.

Create multiple initiator zones and multiple target zones.

B.

Configure igroup and IQN mapping.

C.

Enable NPV on all fabric switches.

D.

Enable NPIV on all fabric switches.

Question 14

An administrator has a NetApp AFF cluster with two SVMs serving LUNs. SnapMirror active sync is configured, and a disaster recovery test is planned over the weekend.

Which NetApp ONTAP command will show the status of this test?

Options:

A.

snapmirror failover show

B.

network interface failover-groups show

C.

storage failover hwassist show

D.

snapnirror config-replication status show

Question 15

A customer opens a support case for performance issues with an FC Oracle database after migrating from a NetApp AFF system to a NetApp All SAN Array (ASA) platform. Further investigation shows that the number of paths exceeds the recommendation for SAN deployment.

What are two ways to address this problem? (Choose two.)

Options:

A.

Use Selective LUN Mapping.

B.

Reconfigure the fabric switch zoning.

C.

Have the database team change their backup and recovery schedules for the database.

D.

Reconfigure the ALUA settings.

Question 16

An administrator is planning a SAN implementation and needs to validate that the ESXI host and NetApp ONTAP software releases are supported.

Which tool is used to accomplish this?

Options:

A.

NetApp Interoperabilty Matrix Tool

B.

NetApp Active IQ Config Advisor

C.

NetApp Hardware Universe

D.

Broadcom SAN Health

Question 17

An administrator has a NetApp AFF cluster supporting an application with twelve LUNs allocated across four volumes. There is a requirement to configure a Snapshot copy of all LUNs simultaneously as a single unit.

Which NetApp ONTAP command should be used to configure this requirement?

Options:

A.

lun igroup create

B.

network port ifgrp create

C.

volume conversion start

D.

vserver consistency-group create

Question 18

A healthcare customer wants to Implement an FC SAN solution consisting of a NetApp ONTAP system, Broadcom switches, and servers.

Which tool contains detailed blueprints and implementation references that can be used to design this solution?

Options:

A.

NetApp Fusion

B.

NetApp Verified Architecture

C.

NetApp Active IQ Config Advisor

D.

NetApp Active IQ Unified Manager

Question 19

What Is a recommended setting for using the NetApp ONTAP LUN fractional reserve?

Options:

A.

LUN space reservation is disabled.

B.

Space allocation is set to enable.

C.

Space guarantee is set to volume.

D.

Volume Snapshot copy automatic deletion is disabled.

Page: 1 / 5
Total 65 questions