Oracle Utilities Meter Solution Cloud Service 2022 Implementation Professional Questions and Answers

Question 1

A business needs a new Service Order process that includes meter commands. Which THREE options should you configure to build this process?

Options:

A.

Measuring component type

B.

Device configuration type

C.

Activity type

D.

Communication type Message sender

Buy Now
Question 2

Which THREE are best practices for measurement retention?

Options:

A.

Derive time-of-use (TOU) values with interval data to prevent storing extra data.

B.

Derive demand from interval data to prevent storing extra data.

C.

Keep scalar measurements in the customer read tables to stay consistent.

D.

Use Information Lifecycle Management (ILM) processes to help archive data.

E.

Keep initial measurement data (IMD) for the same period of time as final measurements for cancel rebill purposes.

Question 3

Your client wants to generate bill determinants for the billing system by using a time-of-use (TOU) group for "on peak", "off peak", and "shoulder." They also want to have holiday consumption categorized as "off peak" regardless of the day on which it falls.

What is the correct configuration for this?

Options:

A.

Edit the TOU map template to include the Holiday TOU as "off peak".

B.

Add the work calendar to the TOU map template and set the Holiday TOU as "off peak".

C.

Add the work calendar to the TOU map template and set the Holiday TOU as "on peak", "off peak", or "shoulder" depending on the calendar day.

D.

Add the work calendar to the TOU map template and set the Holiday TOU as "on peak".

E.

Add the work calendar ta the TOU map template.

Question 4

What are the THREE uses of the Smart Grid Gateway (SGG)?

Options:

A.

Sharing event information with downstream systems

B.

Sharing customer information

C.

Connecting to Smart Meter systems

D.

Communicating directly with meters

E.

Sharing outage information with outage management systems

Question 5

How do you calculate the power factor for a bill?

Options:

A.

Use the Vector and Quantity Math rule to derive the power factor from the kWh and kVArh channels.

B.

Use a virtual meter to perform the calculations.

C.

Use a measuring component derivation algorithm to calculate the power factor.

D.

Power factor can only come from the meter and cannot be calculated.

Question 6

Devices are often added to Meter Data Management (MDM) via a synchronization process. Device configuration business objects (BOs) can be configured to use Synchronization Add BO to determine the appropriate BO for the new device.

What is Synchronization Add BO associated with?

Options:

A.

Business service associated with Dl-Device Configuration BO

B.

Options on Dl-Device Configuration BO

C.

Validation algorithm on Dl-Device Configuration BO

D.

Lifecycle algorithm on Dl-Device Configuration BO

Question 7

For a Meter Data Management (MDM) implementation, a customer requires specific bill determinants along with bill determinant calculation validations to be executed, before the determinant values are exported to their customer information system (CIS).

Which THREE factors should you consider while configuring usage calculation groups?

Options:

A.

CIS rates, that MDM bill determinants or the usage process are expected to support

B.

Bill determinants or usage validations

C.

Bill determinants or usage calculations

D.

Type of measurement (interval or scalar) data that needs to be used for bill determinants or usage calculation

E.

Device subscriptions