67 - Fire Inspector II Exam Questions and Answers

Question 1

The minimum fire-flow for a 3,700-sq. ft. two-family dwelling of Type VB construction with a sprinkler system is ___ GPM.

Options:

A.

875

B.

1,000

C.

1,313

D.

1,750

Buy Now
Question 2

A code official may allow the occupant load of a building or room to exceed that specified in the building code if additional exit facilities are provided, all other egress requirements are met, and the maximum occupancy does not exceed one occupant per sq. ft. of occupiable floor area.

Options:

A.

3

B.

5

C.

7

D.

10

Question 3

A 501 gal. water capacity above-ground liquefied petroleum gas (LP-gas) tank located 20 ft. from a 250 gal. LP-gas tank must be separated a minimum of __ ft. from adjoining property.

Options:

A.

5

B.

10

C.

20

D.

25

Question 4

Given: A health club contains a 1,000-sq. ft. exercise room.

Based on the square footage, what is the calculated occupant load allowed for this exercise room?

Options:

A.

10

B.

20

C.

30

D.

50

Question 5

In a motion picture theatre, an audible announcement shall be made to notify the occupants of the location of exits to be used in the event of a fire or other emergency not more than how many minutes prior to the start of each program?

Options:

A.

5

B.

10

C.

20

D.

30

Question 6

Smoking is not permitted within ___ ft. of a transfer point for LP-gas while filling operations are in progress.

Options:

A.

10

B.

15

C.

25

D.

50

Question 7

Extra-high-rack combustible storage is defined in the fire code as any storage on racks of Class I, II, III, or IV commodities which exceed ___ ft. in height, and any storage on racks of high-hazard commodities which exceed ___ ft. in height.

Options:

A.

20; 30

B.

30; 40

C.

40; 30

D.

50; 40

Question 8

Quantities of flammable liquid storage in a control area of an S Occupancy may be doubled when:

Options:

A.

permission is granted by the chief.

B.

the control area exceeds 50,000 sq. ft.

C.

the building is protected with automatic sprinklers.

D.

the control area is provided with exhaust ventilation in accordance with fire code requirements.

Question 9

A Type I handrail that is not circular shall have a minimum perimeter dimension of ___ inches.

Options:

A.

1.25

B.

2

C.

4

D.

6.25

Question 10

Given: In organic coating processes where Class I liquids are exposed to the air, Class I, Division I electrical installations are required to be outside the immediate vicinity of pumps or equipment.

"Immediate vicinity" means in addition to a vertical distance a zone extending from the vapor liberation point __ ft. horizontally in all directions.

Options:

A.

5

B.

10

C.

20

D.

50

Question 11

When adequate openings are provided on only one exterior wall of a story in an office building, an automatic sprinkler system shall be installed when the wall opposite the openings is more than ___ ft. away.

Options:

A.

50

B.

75

C.

100

D.

150

Question 12

A required standpipe shall be installed when the progress of construction above the lowest level of fire department access reaches a maximum of __ ft.

Options:

A.

30

B.

40

C.

55

D.

75

Question 13

Horizontal exits shall not comprise more than ___ of the required exits from any floor area in a Group I-2 occupancy.

Options:

A.

1/3

B.

1/2

C.

2/3

D.

3/4

Question 14

A building occupied for aerosol storage shall be classified as which of the following occupancy classifications?

Options:

A.

High-hazard Group H

B.

High-hazard Group H-2

C.

High-hazard Group H-3

D.

Group S-1

Question 15

Incineration operations must comply with which of the following requirements?

Options:

A.

Operators must be at least 21 years of age

B.

Incineration which creates an odor when burning requires a fire permit

C.

Fuel-fired incinerators must be preheated for at least 20 minutes before use

D.

Incineration operations must stop if the fire code official determines that the odor is offensive to nearby residents

Question 16

Where requirements for fire safety are not specifically provided for by the International Fire Code, which of the following shall have the responsibility to determine the applicable requirements?

Options:

A.

City manager.

B.

Legal counsel.

C.

Board of appeals.

D.

Fire code official.

Question 17

Paint spray booths must have a clearance of ___ in. from unprotected combustible materials.

Options:

A.

12

B.

18

C.

24

D.

36

Question 18

An acceptance test for a fire alarm system in a new apartment building should be scheduled after:

Options:

A.

each zone is completed.

B.

the contractor verifies full compliance.

C.

the hydrostatic test of the underground main is completed.

D.

the system has been installed and operating for one year.

Question 19

Churches, schools, apartment dwellings, and mercantile structures are commonly built using what type of construction?

Options:

A.

Type I

B.

Type II

C.

Type III

D.

Type IV

Question 20

The occupant load of a building, or portion thereof, may be increased beyond the code's calculated minimum for the Group classification of the building, provided that all other requirements of the code are also met based on the modified number, and the occupant load does not exceed one occupant per ___ sq. ft.

Options:

A.

3

B.

5

C.

7

D.

15

Question 21

Multiple smoke alarms installed within individual guest rooms of a hotel must comply with which of the following requirements?

Options:

A.

Their batteries must be checked every six months.

B.

They must automatically sound a fire alarm throughout the hotel.

C.

They must initiate an automatic fire suppression or sprinkler system.

D.

They must be interconnected so that one alarm will activate all alarms within the guest rooms.

Question 22

Which of the following situations requires securing of an operational permit from the code official prior to commencing the related activity?

Options:

A.

Storing 85,000 bd. ft. of lumber.

B.

Inside storage of 100 cu. ft. of baled cotton.

C.

Fruit ripening operations using carbon dioxide gas.

D.

Organic coating production facility producing 2 gallons per day.

Question 23

Clearance between tops of piles of combustible fibers and sprinkler heads shall not be less than ___ ft.

Options:

A.

2

B.

3

C.

4

D.

5

Question 24

The minimum allowable distance to a public traffic route for storage of 1,750 lb. of Class 1.3 explosives is ___ ft.

Options:

A.

50

B.

75

C.

115

D.

150

Question 25

The fire code official has the right to enter a building to perform inspections in all of the following situations except:

Options:

A.

vacant buildings at any time.

B.

factory floors with permission to enter.

C.

public spaces of a mall during normal business hours.

D.

interior space of a warehouse with an administrative warrant.

Question 26

Given: A nonsprinklered building constructed with protected noncombustible material has a fire-resistive rating of a minimum of 1 hour. What is the most protective type of construction, from the choices below, that meets these parameters?

Options:

A.

IIA

B.

IIB

C.

IIIB

D.

VA