SCT configurator does not require permission application, allowing any user to configure at the specified URL.
Which of the following UPS models support bypass hot-swap? (Multiple Choice)
Which of the following actions does the UPS2000-A take to deal with excessive operating temperatures?
What's difference of a traditional industrial frequency UPS compared with high frequency UPS? (Multiple Choice)
Which of the following advantages does the UPS5000-A have compared with the NXP, 9395, and Galaxy 7000? (Multiple Choice)
APM and NXR need to derate at 30°C, while the UPS5000-E does not need to derate below 40°C.
The UPS5000-A features industry-leading reliability. Which of the following statements is correct about the UPS5000-A reliability design? (Multiple Choice)
The UPS2000-G series (6 kVA to 20 kVA) has the () user interface, which displays the system status in real time.
Which of the following are the standard battery packs for the UPS2000-A-10KRTL? ( ) (Multiple Choice)
The external maintenance bypass of the UPS typically adopts ()-pole circuit breakers.
Battery strings of different brands and the same capacity can be used in parallel.
If the UPS is configured with thirty-two 12 V batteries, the floating charge voltage is ().
Considering that the UPS is fully configured but has a low system load rate in the initial stage, the UPS5000-E is designed with a smart hibernation function, which can improve system load rate to ensure highly efficient operation. In case of smart hibernation, how many redundant power modules does the UPS5000-E have at least?
The input power factor (full load) of the UPS5000A is (), which can efficiently reduce the pollution to the power grid and save the preceding power distribution investment.
Which of the following UPS types does the PS5000-E (50 kVA power module) belongs to? (Multiple Choice)
Do the aisles of the FusionModule800 have skylights? ()
The civil air conditioners used by the FusionModule800 can start automatically after restoration of power failure.
The typical aisle type for the FusionModule800 is ().
The parallel signal cables of the UPS2000-G series (6 kVA to 20 kVA) are connected in () mode, which avoids the impact caused by a faulty parallel cable and enhances parallel system reliability.
The UPS5000 is compatible with module and tower.
The UPS5000-E can realize convenient and simple 2N power supply system only by configuring a ().
With high-efficiency rating, the UPS2000-G series was the first in the industry to earn Energy Star certification from the U.S.
The UPS5000-A-400/500K has good scalability, supporting a maximum of 0 to De used in parallel.
The maximum output power of the UPS5000-E (25-75 kVA) bypass module is 128 kW.
What is the maximum capacity of the UPS5000-E power module?
The THDV of the UPS5000-A at full linear loads is ().
The optional components and features in the typical configuration solution of the FusionModule800 include ().
The backup power supply methods for the FusionModule500 and FusionModule800 include (). (Multiple Choice)
For the 6-kVA UPS2000-G, a 1+1 parallel system requires () DB15 parallel cables to ensure that each UPS is connected by at least two parallel cables and to enhance the parallel system reliability.
When using a UPS5000-E (50 kVA power module) with the actual load of 160 kW, 1+1 rack redundancy, and single UPS backup solution, each rack uses three battery strings, each battery string consists of 40 batteries, and the main switch box capacity is ().
The operating temperature range of the FusionModule800 is -20°C to +45°C, and that for the Fusion Mod ule500 is 0°C to 40°C.
The height of the UPS2000-G battery pack is ( ).
The UPS5000-E (25-125 kVA) only supports top cable routing.