11.11 Special 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: save70

Free and Premium EMC DES-1241 Dumps Questions Answers

Page: 1 / 4
Total 96 questions

Specialist - Platform Engineer PowerStore Exam Questions and Answers

Question 1

A Storage Administrator encounters a Snapshot issue on a Dell EMC PowerStore X system.

The administrator engages support and they determine the Snapshot issue is a known code bug within the OS version of PowerStore code. How can support address the problem in a timely manner?

Options:

A.

Disable the Snapshots feature to avoid encountering the code bug

B.

Upgrade the Snapshot portion of code within the OS

C.

Upgrade the PowerStore with a hotfix that corrects the code bug

D.

Wait for a new full OS release that corrects the code bug

Buy Now
Question 2

A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?

Options:

A.

A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires

B.

CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations

C.

An increased fan speed signal is sent to the surviving fans and the system continues normal operations

D.

Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down

Question 3

Match the correct non-disruptive upgrade process step (answer column) with the correct sub-step (match column).

Options:

Question 4

Which network is used for internal communication?

Options:

A.

Intra-Cluster Data

B.

Intra-Cluster Management

C.

NAD Network

D.

Inter-Node Network

Question 5

How many fan module failures can a node tolerate?

Options:

A.

0

B.

1

C.

2

D.

3

Question 6

What guidance must to be considered for Service LAN port access of a Dell EMC PowerStore appliance?

Options:

A.

Always connect multiple appliances to the same hub or switch

B.

Never connect multiple appliances to the same hub or switch

C.

Never connect the Service laptop directly to the appliance Service LAN port

D.

Always removed the management port connections on the appliance

Question 7

Which port is used to SSH from one Dell EMC PowerStore appliance to another?

Options:

A.

22

B.

26

C.

443

D.

21

Question 8

Which experienced administrator role needs to address a warning about configuring VLTi?

Options:

A.

Storage

B.

VMware distributed switch

C.

Network

D.

NAS

Question 9

Which component is hot-swappable?

Options:

A.

SFP

B.

Fan

C.

BBU

D.

Expansion IO module

Question 10

What is the protocol used for the storage network?

Options:

A.

FC

B.

NFS

C.

SMB

D.

iSCSI

Question 11

In an unpopulated rack, at what U mark is the base enclosure racked?

Options:

A.

3

B.

4

C.

2

D.

1

Question 12

What describes Dell EMC PowerStore X power down?

Options:

A.

PowerStore X node, appliance, or cluster power down is done entirely with vCenter server commands

B.

Powering down a PowerStore X node, appliance, or cluster is done in the same manner as a PowerStore T

C.

PowerStore X node, appliance, or cluster power down utilizes the VSi plugin to perform the needed vCenter server operations

D.

Powering down a PowerStore X node, appliance, or cluster requires additional vCenter server commands

Question 13

From where can a data collection be initiated within Dell EMC PowerStore Manager?

Options:

A.

Appliance, node, and storage resource

B.

Cluster, appliance, and alerts

C.

Cluster, appliance, and event log

D.

Node, storage resource, and alerts

Question 14

How many nodes are in the base enclosure?

Options:

A.

2 nodes configured as Active-Standby

B.

1 node with duel connectivity

C.

1 node with high availability enabled

D.

2 nodes configured as Active-Active

Page: 1 / 4
Total 96 questions