Pre-Winter Special - Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: top65certs

EMC D-PST-MN-A-24 Dumps

Dell PowerStore Maintenance Achievement Questions and Answers

Question 1

In which step of the ICW can the configuration details be exported?

Options:

A.

Support Assist

B.

Cluster Configuration

C.

Cluster Details

Buy Now
Question 2

While on-site installing a Dell EMC PowerStore system, the node A and B embedded module fault LEDs are alternating blue and amber (blue for 3 seconds). What does this

indicate?

Options:

A.

Nodes are in service mode

B.

Nodes are in degraded mode

C.

The system is not initialized

D.

The system is booting

Question 3

Which account credentials are needed to run diagnostic commands?

Options:

A.

console

B.

service

C.

root

D.

admin

Question 4

From where can a data collection be initialized within Dell EMC PowerStore Manager?

Options:

A.

Appliance, node, and storage resource

B.

Cluster, appliance, and event log

C.

Cluster, appliance, and alerts

D.

Node, storage resource, and alerts

Question 5

What is the protocol used for the storage network?

Options:

A.

NFS

B.

FC

C.

iSCSI

D.

SMB

Question 6

Which type of device is supported in expansion enclosures?

Options:

A.

NVMe SCM

B.

SAS SSD

C.

NVMe NVRAM

D.

NVMe SSD

Question 7

A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?

Options:

A.

An increased fan speed signal is sent to the surviving fans and the system continues normal operations

B.

Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down

C.

A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires

D.

CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations

Question 8

How is a service laptop IP configured to connect to the Service LAN port of a Dell EMC PowerStore node?

Options:

A.

Static IP: 169.254.1.249 and netmask: 255.0.0.0

B.

Leave IP address and netmask unconfigured

C.

Static IP: 128.221.1.249 and netmask: 255.255.255.0

D.

Obtain IP address from DHCP on PowerStore

Question 9

Order the NDU operational steps.

Options:

Question 10

Under which condition does the Dell EMC PowerStore equipment in the rack require additional stability?

Options:

A.

Unstable humidity

B.

When shipping the system

C.

Low temperatures

D.

High temperatures

Question 11

Refer to the exhibit.

Which column indicates the primary appliance?

Options:

A.

Mode

B.

Model

C.

IP Address

Question 12

How many fan module failures can a node tolerate?

Options:

A.

3

B.

0

C.

2

Question 13

Which network traffic is encrypted using IPsec?

Options:

A.

Management network

B.

Service network

C.

Internal network

D.

Storage network

Question 14

A Storage Administrator needs to connect through SSH to run svc commands. How is the SSH session configured?

Options:

A.

NAS server IP address using port 22

B.

Appliance IP address using port 26

C.

NAS server IP address using port 26

D.

Appliance IP address using port 22

Question 15

When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?

Options:

A.

svc_node restart

svc_rescue_state start

B.

svc_node shutdown

svc_rescue_state clear

C.

svc_rescue_state clear

svc_node reboot

D.

svc_rescue_state normal

svc_node start

Question 16

A Storage Administrator notices a Critical alert present in Dell EMC PowerStore Manager relating to data integrity. What action within the alert details slide-out panel is helpful in

troubleshooting the problem?

Options:

A.

Examine Notifications to obtain a list of corrective actions

B.

Access the Repair Flow link to schedule a support engagement

C.

Re-engage support through previous listed Related Events

D.

Select the Gather Support Materials from Service and Support

Question 17

What is a step in configuring the ToR data switches for a Dell EMC PowerStore T?

Options:

A.

Configure a port for the discovery laptop

B.

Create VLAN for vMotion networks

C.

Configure ports for management on native VLAN

D.

Create VLANs for NAS server networks

Question 18

What is the result of setting a VLAN ID of 0 on a network when running ICW for Dell EMC PowerStore?

Options:

A.

Default route is set

B.

Network will pass tagged traffic

C.

Network will pass untagged traffic

D.

Static route is set