New Year Special 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: save70

Free and Premium Blue Prism APD01 Dumps Questions Answers

Page: 1 / 2
Total 49 questions

Blue Prism Certified Professional Developer Exam Questions and Answers

Question 1

Which of the following statements about the status of a work queue is/are correct?

1. The status can be used as a method of recording what work has been done so far on a Work Queue item

2. The status is set using the Update Status action of the Work Queues business object

3. Every time the Update Status action is executed, the existing status is appended. Each status is separated with a semi colon.

4. The status can be used to aid manual working of exceptions; providing the Item Status can inform staff what work is still outstanding on an item that needs manually completing

Options:

A.

1, 2, 3 and 4

B.

1, 2 and 4

C.

1, 2 and 3

D.

1 only

Buy Now
Question 2

The ‘Agent’ field on the first row of the table below has been spied as a Region:

A Read Stage is using the ‘Recognise Text’ Data option to read some text from the Region. The result from the stage is shown in the following data item:

Which of the following could be a valid reason for this?

Options:

A.

The application may not have been activated before the Read Stage was executed

B.

The Font specified in the Read stage does not exist in the Blue Prism database

C.

Font Smoothing has been switched off on the Robot PC

D.

The Object is not attached the application

Question 3

An attempt to start a Process on resource BP0100 has resulted in the following error message:

BP0100 is too busy to run that process

Which of the below is the most likely cause of this error?

Options:

A.

Resource BP0100 is offline

B.

There is more than one instance of the Blue Prism resourcepc command running on resource BP0100

C.

The BPServer service is not running on the Blue Prism Application Server

D.

A Process is running on resource BP0100 that calls a Business Object with a run mode of ‘Exclusive’

Question 4

When using Surface Automation Blue Prism is required to read the text contained within the Notes field below:

To do this, the field must be highlighted and the Keystrokes CTRL & C must be sent to the application to copy the text to the clipboard.

The Note Box has been identified as a Region within the following Application Model.

Assuming all the text in the Notes field has been successfully highlighted, which of the following stages will successfully send CTRL & C to the application to copy the highlighted text to the Clipboard?

Options:

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Question 5

Which of the following statements regarding Blue Prism Login Agent are true? (Select all that apply.)

Options:

A.

Windows passwords can be changed using Login Agent Functionality

B.

It is not possible to use Login Agent to traverse the ‘Press CTRL + ALT + DELETE to log on’ screen

C.

Blue Prism Login Agent can be used to lock a Resource PC

D.

You cannot configure the Blue Prism scheduler to login via Login Agent and then run a business process once it has logged in

Question 6

Which of the following is a recommend tip for dealing with problems when launching and attaching to Browser Applications?

Options:

A.

Use the Start Process action of the Utility - Environment Object to launch the application followed by an attach stage to attach to the application

B.

Hold the target URL in a data item as opposed to it being configured in the Application Modeller Wizard

C.

Set the HKEY CURRENT USER\Software\Microsoft\Internet Explorer\Main\TabProcGrowth Registry key to 2

D.

Use Surface Automation to automate the application

Question 7

While automating a process involving a browser based application a popup window from the browser application appears that you need to work with. When you try to spy the popup window and its elements, Blue Prism throws the following error: “There was an error during the spying operation.” Which of the following would be the most appropriate workaround?

Options:

A.

Set the HKEY CURRENT USER\Software\Microsoft\Internet Explorer\Main\TabProcGrowth Registry key to 2

B.

Change the scope of the process so that the popup window does not need to be automated

C.

Create a new separate object that attaches to the running instance of the popup and attempt to spy elements with this object instead.

D.

Use Surface Automation techniques to interface with the popup window

Page: 1 / 2
Total 49 questions